Vertical Hot-water Boiler /Oil Hot Water Boiler (0.06-1.4MW) (g)
Product Details:
| Structure | Fire Tube |
|---|---|
| Style | Vertical |
| Pressure | Low Pressure |
| Usage | Industrial |
| Fuel | Oil-fired |
| Output | Hot Water |
| Type | Natural Circulation |
| Place of Origin | Jiangsu, China (Mainland) |
| Brand Name | WILFORD |
| Model Number | CWNS0.7-85/60-Y |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 Set/Sets |
|---|---|
| Packaging Details: | boiler proper nude, accessories in plywood case |
| Delivery Time: | 20 working days |
| Payment Terms: | T/T |
| Supply Ability: | 20 Set/Sets per Month |
Detailed Product Description
1. CWNS series of hot water boiler is three return trip back all wet big chamber boiler shells, the main structure be made of the shell pan, oven bile, changing breathing room, convection control components, convection breathing tube is threaded pipe used to enhance heat transfer.
2. Furnace big, high radiate, three return design, combustion air is full, high-efficiency heating surface. Application breathing tube additional spoiler film technology, not only expansion of heat, the dust and its "self-cleaning" feature can reduce thermal resistance, improve heat transfer effectiveness. Using high thermal resistance of insulation materials, boilers, heat losses to the minimum
3. More than 90% thermal efficiency. Intelligent, automatically control, with automatic temperature regulation, over-temperature standby. Freezing cold winter night, and other functions, and to achieve the outdoor temperature changes automatically adjust the temperature heating function to maximize energy conservation.
4. Burners are used by importing, pressure spray, burning completely, low noise. thus Combustion intensity will be reduced dust emissions reduction of harmful gases such as NO x emissions reduced to the minimum, to meet stringent environmental requirements
5. Confined by connecting structure, safe, reliable, long service life. Super temperature, cut water, overload, ignition failure, abnormal flameout, gas boiler pressure, all can do self-test multiple chain protection. Expansion of water testing through the atmosphere, atmospheric pressure operation, there are no all potential safety problems.
| Type | CLHS0.06-95/70-Y.Q | CLHS0.12-95/70-Y.Q | CLHS0.17-95/70-Y.Q | CLHS0.23-95/70-Y.Q | CLHS0.35-95/70-Y.Q | CLHS0.47-95/70-Y.Q | CLHS0.58-95/70-Y.Q | CWNS0.7-95/70-Y.Q | CWNS1.05-95/70-Y.Q | CWNS1.4-95/70-Y.Q | CWNS1.75-95/70-Y.Q | CWNS2.1-95/70-Y.Q | CWNS2.8-95/70-Y.Q | ||
| Project | Unit | ||||||||||||||
| Rated heat | MW | 0.06 | 0.12 | 0.17 | 0.23 | 0.35 | 0.47 | 0.58 | 0.7 | 1.05 | 1.4 | 1.75 | 2.1 | 2.8 | |
| total heat | 104kcal | 5 | 10 | 15 | 20 | 30 | 40 | 50 | 60 | 90 | 120 | 150 | 180 | 240 | |
| Rated working pressure | MPa | atmosphric pressure | |||||||||||||
| Fuel consumption | Light diesel oil | kg/h | 5.4 | 10.8 | 16.2 | 21.6 | 32.5 | 43.2 | 54 | 65 | 97.5 | 130 | 162 | 195 | 260 |
| Natural gas | Nm3/h | 5.8 | 11.7 | 17.5 | 23.4 | 35 | 46.8 | 58.5 | 70 | 105 | 140 | 175 | 210 | 280 | |
| Liquefied gas | Nm3/h | 2.5 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 45 | 60 | 75 | 90 | 120 | |
| Pipeline gas | Nm3/h | 14.2 | 28.3 | 42.5 | 56.6 | 85 | 113.2 | 141.5 | 170 | 255 | 340 | 425 | 510 | 680 | |
| Infall caliber | DN | 50 | 65 | 65 | 65 | 65 | 80 | 100 | 100 | 125 | 150 | 150 | 200 | 200 | |
| Effluent caliber | DN | 50 | 65 | 65 | 65 | 65 | 80 | 100 | 100 | 125 | 150 | 150 | 200 | 200 | |
| Blowndown valve caliber | DN | 25 | 25 | 25 | 25 | 25 | 40 | 40 | 50 | 50 | 50 | 50 | 65 | 65 | |
| Voltage | V | 220 | 220 | 220 | 220 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | |
| Overall size | Length | mm | 800 | 980 | 1150 | 1250 | 1500 | 1550 | 1600 | 3020 | 3230 | 3650 | 4100 | 4550 | 5600 |
| Width | mm | 700 | 850 | 900 | 1000 | 1200 | 1250 | 1450 | 1700 | 1750 | 1820 | 1890 | 1930 | 2000 | |
| Hight | mm | 1300 | 1650 | 1800 | 1950 | 2000 | 2100 | 2500 | 1880 | 1960 | 2050 | 2100 | 2150 | 2270 | |
| Weight | kg | 270 | 410 | 450 | 520 | 830 | 980 | 1500 | 2450 | 2780 | 3500 | 3860 | 4520 | 6300 | |
Parameter
Type: CWNS0.7--85/60-Y
Power: 0.7MW
Working Pressure: Atmospheric pressure
Outlet water Temp.: 85 Degree C
WaterreturnTemp.: 60 Degree C
Fuel: Oil
Length: 3000mm
Width: 1700mm
High: 1880mm
Weight: 2450kg
Vertical Hot-water Boiler /Oil Hot Water Boiler (0.06-1.4MW) (g)
Other Products from this Supplier
See more
hot water boiler, oil hot water boiler, hot water generator products from this supplier.
Products
- Oil Fired Steam Boiler [89]
- Gas Fired Steam Boiler [64]
- Heavy oil fired Steam Boiler [6]
- mutil-fuel fired steam boiler [5]
- Electric heating Steam Boiler [50]
- Gas/oil fired Steam Generator [42]
- Electric Steam generator [36]
- Oil/gas fied Hotwater Boiler [38]
- Electric heating Hotwater Boiler [20]
- Auxiliary Equipment-Plastic Recycling Machinery [3]
- Others [6]
Company Info
Zhangjiagang Wilford Thermal Technology Co., Ltd.
[China (Mainland)]
[Verified Member]
City: Suzhou
Province/State: Jiangsu
Country/Region : China (Mainland)
Business Type:Manufacturer
Online Postings: Products